SIMULASI NUMERIK PENGARUH DIAMETER DAN KECEPATAN ALIRAN TERHADAP PERFORMANSI SINGLE SERPENTINE CHANNEL PADA PV
DOI:
https://doi.org/10.33019/jm.v10i1.4010Keywords:
Photovoltaic, PV Cooling, Diameter, Flow Rate.Abstract
The application of photovoltaic energy (PV) is currently very massive due to the savings and implementation of new and renewable energy. In the use of PV, an increase in temperature affects the optically generated electrical power. One way to reduce the PV temperature is by optimizing the design of the cooling channel. The method used in this research is a three-factor factorial design where the variable that is set is a diameter of 1.5 inches; 2 inches; and 2.5 inches and an inlet flow rate of 0.5 ; 0.6 ; and 0.7 , using CFD along with analytical calculations. The results showed that the 2.5 inch diameter configuration with a speed of 0.7 m/s produced an average temperature of 30.188 ℃ while the 1.5 inch configuration with a speed of 0.5 m/s produced an average temperature of 36.664℃. The temperature becomes lower with the larger pipe diameter configuration and the use of higher fluid velocity
Downloads
Downloads
Published
Issue
Section
License
The paper presented is assumed not to contain proprietary materials that are not protected by patents or patent applications. Responsibility for technical content and for protection from proprietary materials is the responsibility of the author and their organization and not the responsibility of the machine or its editorial staff. The primary author (first / appropriate) is responsible for ensuring that the article has been viewed and approved by all other authors. It is the responsibility of the author to obtain all copyright release permits required for the use of any copyrighted material in the manuscript before submission.